Greece Daily Load Shape and Duck Curve by Hour, 23 August to 19 September 2026
In the 28 complete local days from 23 August to 19 September 2026, electricity demand in Greece averaged 6,465 MW and typically peaked at 14:00 local time (7,615 MW) and bottomed out at 05:00 (5,028 MW). With solar and wind taken off, the remaining load fell to -819 MW at 12:00 and then rose 5,026 MW between 16:00 to 19:00. Hours are local clock time (Europe/Athens).
Key Facts
Over 28 complete local days from 23 August to 19 September 2026, average demand in Greece was 6,465 MW. The hour of the day with the highest average demand was 14:00 local time (7,615 MW) and the lowest was 05:00 (5,028 MW).
The largest three hour rise in average demand was 9 MW, between 17:00 to 20:00 local time.
The single highest hour of demand in the 30 day window was 9,022 MW, in the hour starting 26 Aug 2026, 14:00 EEST (UTC+03:00).
Solar output averaged 7,336 MW at its 13:00 peak, 113% of average demand.
Demand minus solar and wind (net load) averaged 3,025 MW, fell to -819 MW at 12:00 and rose 5,026 MW over the three hours from 16:00 to 19:00, 78% of average demand.
Average Day by Local Hour
28 days to 2026-09-19, Europe/Athens time
DemandNet generation
Average electricity demand in Greece by local clock hour over 28 complete local days from 23 August to 19 September 2026. It was lowest at 05:00 (5,028 MW) and highest at 14:00 (7,615 MW). Net generation is the power produced inside the grid, so it differs from demand by net imports.
Mean MW by local hour, 2026-08-23 to 2026-09-19
Greece average demand and net generation by local hour
Local hour (Europe/Athens)
Demand
Net generation
00:00
5,915 MW
5,720 MW
01:00
5,568 MW
5,358 MW
02:00
5,320 MW
5,180 MW
03:00
5,146 MW
5,002 MW
04:00
5,037 MW
4,985 MW
05:00
5,028 MW
5,150 MW
06:00
5,209 MW
5,425 MW
07:00
5,457 MW
5,921 MW
08:00
5,904 MW
6,930 MW
09:00
6,370 MW
7,834 MW
10:00
6,746 MW
8,300 MW
11:00
7,061 MW
8,499 MW
12:00
7,365 MW
8,830 MW
13:00
7,576 MW
9,013 MW
14:00
7,615 MW
8,903 MW
15:00
7,471 MW
8,571 MW
16:00
7,331 MW
8,234 MW
17:00
7,274 MW
7,628 MW
18:00
7,277 MW
7,123 MW
19:00
7,220 MW
6,684 MW
20:00
7,283 MW
6,645 MW
21:00
7,080 MW
6,680 MW
22:00
6,652 MW
6,111 MW
23:00
6,264 MW
877 MW
DemandNet load (demand minus solar and wind)
Average demand and net load (demand minus solar and wind) in Greece by local clock hour over 28 complete local days from 23 August to 19 September 2026. Net load was lowest at 12:00 (-819 MW) and then rose 5,026 MW between 16:00 to 19:00.
Mean MW by local hour, 2026-08-23 to 2026-09-19
Greece duck curve: demand and net load by local hour
Local hour (Europe/Athens)
Demand
Net load (demand minus solar and wind)
00:00
5,915 MW
5,029 MW
01:00
5,568 MW
4,663 MW
02:00
5,320 MW
4,347 MW
03:00
5,146 MW
4,071 MW
04:00
5,037 MW
3,869 MW
05:00
5,028 MW
3,771 MW
06:00
5,209 MW
3,870 MW
07:00
5,457 MW
3,815 MW
08:00
5,904 MW
2,826 MW
09:00
6,370 MW
1,228 MW
10:00
6,746 MW
-33 MW
11:00
7,061 MW
-568 MW
12:00
7,365 MW
-819 MW
13:00
7,576 MW
-803 MW
14:00
7,615 MW
-481 MW
15:00
7,471 MW
31 MW
16:00
7,331 MW
950 MW
17:00
7,274 MW
2,612 MW
18:00
7,277 MW
4,672 MW
19:00
7,220 MW
5,975 MW
20:00
7,283 MW
6,294 MW
21:00
7,080 MW
6,125 MW
22:00
6,652 MW
5,760 MW
23:00
6,264 MW
5,387 MW
SolarWind
Average solar and wind generation in Greece by local clock hour over 28 complete local days from 23 August to 19 September 2026. Solar peaked at 13:00 at 7,336 MW.
Mean MW by local hour, 2026-08-23 to 2026-09-19
Greece average solar and wind output by local hour
Local hour (Europe/Athens)
Solar
Wind
00:00
0 MW
885 MW
01:00
0 MW
905 MW
02:00
0 MW
973 MW
03:00
0 MW
1,075 MW
04:00
0 MW
1,168 MW
05:00
0 MW
1,257 MW
06:00
3 MW
1,335 MW
07:00
278 MW
1,365 MW
08:00
1,784 MW
1,294 MW
09:00
3,950 MW
1,192 MW
10:00
5,637 MW
1,142 MW
11:00
6,555 MW
1,074 MW
12:00
7,126 MW
1,058 MW
13:00
7,336 MW
1,043 MW
14:00
7,080 MW
1,016 MW
15:00
6,414 MW
1,025 MW
16:00
5,258 MW
1,124 MW
17:00
3,526 MW
1,136 MW
18:00
1,522 MW
1,083 MW
19:00
231 MW
1,013 MW
20:00
4 MW
985 MW
21:00
0 MW
955 MW
22:00
0 MW
892 MW
23:00
0 MW
877 MW
Average Greece demand, net generation, solar, wind and net load by local hour
Local hour
Demand
Net generation
Solar
Wind
Net load
00:00
5,915 MW
5,720 MW
0 MW
885 MW
5,029 MW
01:00
5,568 MW
5,358 MW
0 MW
905 MW
4,663 MW
02:00
5,320 MW
5,180 MW
0 MW
973 MW
4,347 MW
03:00
5,146 MW
5,002 MW
0 MW
1,075 MW
4,071 MW
04:00
5,037 MW
4,985 MW
0 MW
1,168 MW
3,869 MW
05:00
5,028 MW
5,150 MW
0 MW
1,257 MW
3,771 MW
06:00
5,209 MW
5,425 MW
3 MW
1,335 MW
3,870 MW
07:00
5,457 MW
5,921 MW
278 MW
1,365 MW
3,815 MW
08:00
5,904 MW
6,930 MW
1,784 MW
1,294 MW
2,826 MW
09:00
6,370 MW
7,834 MW
3,950 MW
1,192 MW
1,228 MW
10:00
6,746 MW
8,300 MW
5,637 MW
1,142 MW
-33 MW
11:00
7,061 MW
8,499 MW
6,555 MW
1,074 MW
-568 MW
12:00
7,365 MW
8,830 MW
7,126 MW
1,058 MW
-819 MW
13:00
7,576 MW
9,013 MW
7,336 MW
1,043 MW
-803 MW
14:00
7,615 MW
8,903 MW
7,080 MW
1,016 MW
-481 MW
15:00
7,471 MW
8,571 MW
6,414 MW
1,025 MW
31 MW
16:00
7,331 MW
8,234 MW
5,258 MW
1,124 MW
950 MW
17:00
7,274 MW
7,628 MW
3,526 MW
1,136 MW
2,612 MW
18:00
7,277 MW
7,123 MW
1,522 MW
1,083 MW
4,672 MW
19:00
7,220 MW
6,684 MW
231 MW
1,013 MW
5,975 MW
20:00
7,283 MW
6,645 MW
4 MW
985 MW
6,294 MW
21:00
7,080 MW
6,680 MW
0 MW
955 MW
6,125 MW
22:00
6,652 MW
6,111 MW
0 MW
892 MW
5,760 MW
23:00
6,264 MW
877 MW
0 MW
877 MW
5,387 MW
Each value is the mean over 28 complete local days from 23 August to 19 September 2026, weekdays and weekends together, for the hour starting at that local clock time.
Net load is demand minus solar and wind generation. The single highest hour of demand in the whole 30 day window was 9,022 MW; it is a published reading, not an average, and is not part of the profile above.
Source: ENTSO-E Transparency Platform (transparency.entsoe.eu), CC BY 4.0. Aggregated and converted by World Power Monitor; ENTSO-E does not endorse this site. (ENTSO-E Terms of Use plus CC BY 4.0 for listed data items) Data as of 2026-09-19. Profiles are computed by World Power Monitor from the operator's hourly series.
Assumptions
Hours are local clock time in Europe/Athens. A local day is used only if it is whole inside the 30 day window and at least 22 of its hours are complete; the profile uses the 28 most recent such days. Daylight saving follows the local clock: on a clock change day the missing hour is absent and the repeated hour is averaged over both readings.
The average mixes weekdays and weekends and covers only 28 days, so it describes recent conditions, not a seasonal norm.
The evening ramp is the largest rise over three hours in the average profile, starting between 14:00 and 20:00 local time.